Magnetic resonance imaging of cardiomyocyte apoptosis with a novel magneto-optical nanoparticle

Vertical Tabs

Magn Reson Med
2005 Sep
54
3
718-24
10.1002/mrm.20617
Journal Articles
PubMed ID: 
16086367

The ability to image cardiomyocyte apoptosis in vivo with high-resolution MRI could facilitate the development of novel cardioprotective therapies. The sensitivity of the novel nanoparticle AnxCLIO-Cy5.5 for cardiomyocyte apoptosis was thus compared in vitro to that of annexin V-FITC and showed a high degree of colocalization. MRI was then performed, following transient coronary artery (LAD) occlusion, in five mice given AnxCLIO-Cy5.5 and in four mice given an identical dose (2 mg Fe/kg) of CLIO-Cy5.5. MR signal intensity and myocardial T2* were evaluated, in vivo, in hypokinetic regions of myocardium in the LAD distribution. Ex vivo fluorescence imaging was performed to confirm the in vivo findings. Myocardial T2* was significantly lower in the mice given AnxCLIO-Cy5.5 (8.1 versus 13.2 ms, P

Year: 
2005