Error message

  • Deprecated function: Creation of dynamic property MergeQuery::$condition is deprecated in MergeQuery->__construct() (line 1357 of /webdata/web/html/includes/database/query.inc).
  • Deprecated function: Creation of dynamic property DatabaseCondition::$stringVersion is deprecated in DatabaseCondition->compile() (line 1887 of /webdata/web/html/includes/database/query.inc).
  • Deprecated function: Creation of dynamic property DatabaseCondition::$stringVersion is deprecated in DatabaseCondition->compile() (line 1887 of /webdata/web/html/includes/database/query.inc).
  • Deprecated function: Creation of dynamic property DatabaseCondition::$stringVersion is deprecated in DatabaseCondition->compile() (line 1887 of /webdata/web/html/includes/database/query.inc).
  • Deprecated function: Creation of dynamic property DatabaseCondition::$stringVersion is deprecated in DatabaseCondition->compile() (line 1887 of /webdata/web/html/includes/database/query.inc).

Vectorial total generalized variation for accelerated multi-channel multi-contrast MRI

Vertical Tabs

Magn Reson Imaging
2016 Jun 2
34
8
1161-1170
10.1016/j.mri.2016.05.014
Epub Date: 
Thursday, June 2, 2016
Journal Articles
PubMed ID: 
27262829

PURPOSE: To develop and implement an efficient reconstruction technique to improve accelerated multi-channel multi-contrast MRI.
THEORY AND METHODS: The vectorial total generalized variation (TGV) operator is used as a regularizer for the sensitivity encoding (SENSE) technique to improve image quality of multi-channel multi-contrast MRI. The alternating direction method of multipliers (ADMM) is used to efficiently reconstruct the data. The performance of the proposed method (MC-TGV-SENSE) is assessed on two healthy volunteers at several acceleration factors.
RESULTS: As demonstrated on the in vivo results, MC-TGV-SENSE had the lowest root-mean-square error (RMSE), highest structural similarity index, and best visual quality at all acceleration factors, compared to other methods under consideration. MC-TGV-SENSE yielded up to 17.3% relative RMSE reduction compared to the widely used total variation regularized SENSE. Furthermore, we observed that the reconstruction time of MC-TGV-SENSE is reduced by approximately a factor of two with comparable RMSEs by using the proposed ADMM-based algorithm as opposed to the more commonly used Chambolle-Pock primal-dual algorithm for the TGV-based reconstruction.
CONCLUSION: MC-TGV-SENSE is a better alternative than the existing reconstruction methods for accelerated multi-channel multi-contrast MRI. The proposed method exploits shared information among the images (MC), mitigates staircasing artifacts (TGV), and uses the encoding power of multiple receiver coils (SENSE).