Error message

  • Deprecated function: Creation of dynamic property MergeQuery::$condition is deprecated in MergeQuery->__construct() (line 1357 of /webdata/web/html/includes/database/query.inc).
  • Deprecated function: Creation of dynamic property DatabaseCondition::$stringVersion is deprecated in DatabaseCondition->compile() (line 1887 of /webdata/web/html/includes/database/query.inc).
  • Deprecated function: Creation of dynamic property DatabaseCondition::$stringVersion is deprecated in DatabaseCondition->compile() (line 1887 of /webdata/web/html/includes/database/query.inc).
  • Deprecated function: Creation of dynamic property DatabaseCondition::$stringVersion is deprecated in DatabaseCondition->compile() (line 1887 of /webdata/web/html/includes/database/query.inc).
  • Deprecated function: Creation of dynamic property DatabaseCondition::$stringVersion is deprecated in DatabaseCondition->compile() (line 1887 of /webdata/web/html/includes/database/query.inc).

Neuroimage. 2007 Oct 1;37(4):1227-36 doi: 10.1016/j.neuroimage.2007.06.024. 2007 Jul 10.

Signal and noise characteristics of SSFP FMRI: a comparison with GRE at multiple field strengths

Miller KL, Smith SM, Jezzard P, Wiggins GC, Wiggins CJ.

Abstract

Recent work has proposed the use of steady-state free precession (SSFP) as an alternative to the conventional methods for obtaining functional MRI (FMRI) data. The contrast mechanism in SSFP is likely to be related to conventional FMRI signals, but the details of the signal changes may differ in important ways. Functional contrast in SSFP has been proposed to result from several different mechanisms, which are likely to contribute in varying degrees depending on the specific parameters used in the experiment. In particular, the signal dynamics are likely to differ depending on whether the sequence is configured to scan in the SSFP transition band or passband. This work describes experiments that explore the source of SSFP FMRI signal changes by comparing SSFP data to conventional gradient-recalled echo (GRE) data. Data were acquired at a range of magnetic field strengths and repetition times, for both transition band and passband methods. The signal properties of SSFP and GRE differ significantly, confirming a different source of functional contrast in SSFP. In addition, the temporal noise properties are significantly different, with important implications for SSFP FMRI sequence optimisation.

PMID: 17706432
| MGH/HST Martinos Center for Biomedical Imaging

Error

The website encountered an unexpected error. Please try again later.