Magnetic Resonance Imaging (MRI)

Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI

UNLABELLED: PET combined with CT has proven to be a valuable multimodality imaging device revealing both functional and anatomic information. Although PET/CT has become completely integrated into routine clinical application and also has been used in small-animal imaging, CT provides only limited soft-tissue contrast and, in preclinical studies, exposes the animal to a relatively high radiation dose. Unlike CT, MRI provides good soft-tissue contrast even without application of contrast agents and, furthermore, does not require ionizing radiation.

Publication Type: 
Journal Articles
Journal: 
J Nucl Med

Simultaneous PET-MRI: a new approach for functional and morphological imaging

Noninvasive imaging at the molecular level is an emerging field in biomedical research. This paper introduces a new technology synergizing two leading imaging methodologies: positron emission tomography (PET) and magnetic resonance imaging (MRI). Although the value of PET lies in its high-sensitivity tracking of biomarkers in vivo, it lacks resolving morphology. MRI has lower sensitivity, but produces high soft-tissue contrast and provides spectroscopic information and functional MRI (fMRI). We have developed a three-dimensional animal PET scanner that is built into a 7-T MRI.

Publication Type: 
Journal Articles
Journal: 
Nat Med

Simultaneous PET-MRI in oncology: a solution looking for a problem?

With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously must be balanced against the substantial costs and other requirements of such devices.

Publication Type: 
Journal Articles
Journal: 
Magn Reson Imaging

PET Performance Evaluation of an MR-Compatible PET Insert

A magnetic resonance (MR) compatible positron emission tomography (PET) insert has been developed in our laboratory for simultaneous small animal PET/MR imaging. This system is based on lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiode (PSAPD) photodetectors. The PET performance of this insert has been measured. The average reconstructed image spatial resolution was 1.51 mm. The sensitivity at the center of the field of view (CFOV) was 0.35%, which is comparable to the simulation predictions of 0.40%.

Publication Type: 
Journal Articles
Journal: 
IEEE Trans Nucl Sci

Simultaneous in vivo positron emission tomography and magnetic resonance imaging

Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging.

Publication Type: 
Journal Articles
Journal: 
Proc Natl Acad Sci U S A

Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging

PURPOSE: We propose a novel approach for PET respiratory motion correction using tagged-MRI and simultaneous PET-MRI acquisitions.

Publication Type: 
Journal Articles
Journal: 
Med Phys

PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet

PURPOSE: To prospectively use compact avalanche photodiodes instead of photomultiplier tubes to integrate a positron emission tomographic (PET) detector and a 7-T magnetic resonance (MR) imager.

Publication Type: 
Journal Articles
Journal: 
Radiology

MRI-based nonrigid motion correction in simultaneous PET/MRI

UNLABELLED: Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application.

Publication Type: 
Journal Articles
Journal: 
J Nucl Med

Probabilistic atlas-based segmentation of combined T1-weighted and DUTE MRI for calculation of head attenuation maps in integrated PET/MRI scanners

We present a new MRI-based attenuation correction (AC) approach for integrated PET/MRI systems that combines both segmentation- and atlas-based methods by incorporating dual-echo ultra-short echo-time (DUTE) and T1-weighted (T1w) MRI data and a probabilistic atlas. Segmented atlases were constructed from CT training data using a leave-one-out framework and combined with T1w, DUTE, and CT data to train a classifier that computes the probability of air/soft tissue/bone at each voxel.

Publication Type: 
Journal Articles
Journal: 
Am J Nucl Med Mol Imaging

Gadofosveset-enhanced magnetic resonance imaging of human carotid atherosclerotic plaques: a proof-of-concept study

OBJECTIVE: To investigate the potential of gadofosveset-enhanced MR imaging for the characterization of human carotid atherosclerotic plaques.

Publication Type: 
Journal Articles
Journal: 
Invest Radiol